    Liquid Metal Limiter - Ds18s20 temperature sensors - Inp. Superior - Dep. Inferior - Bypass - Troço Inferior - Dep. Superior - Colector - 4 Vaves  The dsPic acquires the temperature and send it back to a high level PC application. It also control four valves by logic gates with two states, this information is sent back to the PC, there are two commads to control the valve state from the high level application.  Process Value in the IOC Server for this system. PV Name PV Type Archive Localization ISTTOK:gallium:Uptime longin no N/A ISTTOK:gallium:Diff_Uptime calc no N/A ISTTOK:gallium:Last_Uptime calc no N/A ISTTOK:gallium:Temperature_0 ai yes Upper Section, (e) ISTTOK:gallium:Temperature_1 ai yes Lower Deposit, (b) ISTTOK:gallium:Temperature_2 ai yes Bypass, (d) ISTTOK:gallium:Temperature_3 ai yes Lower Section, (f) ISTTOK:gallium:Temperature_4 ai yes  Upper Deposit, (a) ISTTOK:gallium:Temperature_5 ai yes Collector, (c) ISTTOK:gallium:Valve_1 bo no (1) ISTTOK:gallium:Valve_1_RBV bi no (1) ISTTOK:gallium:Valve_2 bo no (2) ISTTOK:gallium:Valve_2_RBV bi no (2) ISTTOK:gallium:Valve_3 bo no (3) ISTTOK:gallium:Valve_3_RBV bi no (3) ISTTOK:gallium:Valve_4 bo no (4) ISTTOK:gallium:Valve_4_RBV bi no (4)   Temperature Sensors and ELCO Voltage Measurement Systems

    ...

    Version from 14:48, 18 Nov 2014

    This revision modified by gquintal (Ban)

    ...


    ...

    Liquid Metal Limiter

    - Ds18s20 temperature sensors

    - Inp. Superior

    - Dep. Inferior

    - Bypass

    - Troço Inferior

    - Dep. Superior

    - Colector

    - 4 Vaves

    The dsPic acquires the temperature and send it back to a high level PC application. It also control four valves by logic gates with two states, this information is sent back to the PC, there are two commads to control the valve state from the high level application. 

    Process Value in the IOC Server for this system.

    PV Name PV Type Archive Localization
    ISTTOK:gallium:Uptime longin no N/A
    ISTTOK:gallium:Diff_Uptime calc no N/A
    ISTTOK:gallium:Last_Uptime calc no N/A
    ISTTOK:gallium:Temperature_0 ai yes Upper Section, (e)
    ISTTOK:gallium:Temperature_1 ai yes Lower Deposit, (b)
    ISTTOK:gallium:Temperature_2 ai yes Bypass, (d)
    ISTTOK:gallium:Temperature_3 ai yes Lower Section, (f)
    ISTTOK:gallium:Temperature_4 ai yes  Upper Deposit, (a)
    ISTTOK:gallium:Temperature_5 ai yes Collector, (c)
    ISTTOK:gallium:Valve_1 bo no (1)
    ISTTOK:gallium:Valve_1_RBV bi no (1)
    ISTTOK:gallium:Valve_2 bo no (2)
    ISTTOK:gallium:Valve_2_RBV bi no (2)
    ISTTOK:gallium:Valve_3 bo no (3)
    ISTTOK:gallium:Valve_3_RBV bi no (3)
    ISTTOK:gallium:Valve_4 bo no (4)
    ISTTOK:gallium:Valve_4_RBV bi no (4)

    ...